Making Trade Life Easy!
101-051

101-051 NESS V200 16-INPUT SUB-CONTROLLER


Contact us for a price

101-051 NESS V200 16-INPUT SUB-CONTROLLER

The V200 input monitor interface connects up to 16 supervised input circuits and provides 2 Aux outputs. Each input monitors and reports normal, off-normal, and alarm states. The V200 connects to the V1000 via a high speed RS-485 network.

The Ness V-Series products provide a complete and fully featured hardware/firmware infrastructure for access control software host systems. The V200 Input Monitor Sub-Controller connects up to 16 supervised input circuits. Each input point monitors and reports normal, off-normal, and alarm states. The V200 features on-board flash memory, allowing program updates to be downloaded through the network. The V200 connects to the V1000 via a high speed RS-485 network. The V1000, in turn, communicates with the system host via industry standard TCP/IP protocol, over 10/100 Mbps Ethernet, or the Internet. This architecture minimizes the impact on corporate LANs, by using only one TCP/IP address for every 32 sub-controllers and by handling low-level transactions on the RS-485 network.

 

BENEFITS

Reports supervised or un-supervised alarm circuits.

Off-normal condition programmable for each input point (NO or NC alarm devices may be used).

Connects to the V1000 via RS-485.

Receives and processes real time commands from the V1000.

Reports all activity to the V1000.

Allows complex input/output linking when used with the V1000 and V300.

Attractive polycarbonate enclosure protects components from damage.

All connections and indicators are fully identified by silk-screened nomenclature on the cover.

UL 294 and UL 1076 recognized components.

VISUAL INdICATORS Communications LEd flashes green for “transmit to host” and red for “receive from host.” Power LEd indicates that sufficient dC voltage is being provided to the unit.

 

Features

EASYLY INTERFACED

Quick-disconnect screw terminal connectors

Rotary address switch (0-15)

Inputs for: 

16 input circuits

AC Fail Monitor*

Battery Fail Monitor*

Enclosure Tamper*

*Can be configured as a general purpose input

 

NON-LATCHING RELAY OUTPUTS 

(rated 2A @ 30 VdC):

2 auxiliary devices: alarm host offline (comms down), orgeneral purpose 

LOCAL PROCESSING

Basic input/output linking using inputs 1 and 2, and auxiliary outputs 1 and 2

 

TECHNICAL SPECIFICATIONS

 Specifications

dIMENSIONS: 147.32 mm W x 122.55 mm h x 32.38 mm 

WEIghT: 350g

ENCLOSURE MATERIAL: UL94 Polycarbonate

POWER SUPPLy REQUIREMENTS: 50 mA @ 9-18 VdC

Recommended: Supervised linear power supply with battery backup, input surge protection, and AC Fail and Battery Low contact outputs.

Separate supervised dC supply with battery back-up recommended for relay activated devices.

OPERATINg ENVIRONMENT Indoors, or customer-supplied NEMA-4 Enclosure

TEMPERATURE: 0° to 50° C hUMIdITy: 5% to 95% relative, non-condensing

COMMUNICATION PORTS RS-485 – two wire.

CERTIFICATIONS
UL 294 and UL 1076 Recognized Component for the US
CSA 205 for Canada
FCC Class A Verification
EMC for Canada, EU (CE Mark), Australia (C-Tick Mark), New Zealand, Japan
EN 50130-4 Access Control Systems Immunity for the EU (CE Mark)

CABLE dISTANCE
RS-485 – 1220m per network to host, using Belden 3105A, 22AWg twisted pair, shielded 100 Ohm cable
Input Circuits – 150 m, 2-conductor, shielded, using ALPhA 1292C (22AWg) or Alpha 2421C (18AWg)
Output Circuits – 150 m, 2-conductor, using ALPhA 1172C (22AWg) or Alpha 1897C (18AWg) Minimum wire gauge depends on cable length and current requirements.