Fast 10-ms Sampling. Up to 600 Channels Data Logging
  • Capture data with 15 to a maximum of 600 channels
  • Send data to the PC in real time
  • Isolated to sustain up to 600 V between modules and earth
  • USB 2.0, LAN 100BASE-TX, Store to 1GB PC Card
  • Simultaneous fast- and low-speed sampling allows for media storage space effi ciency
Note: 8423 cannot operate alone. You must install one or more optional input modules in the unit. Thermocouples are not provided by HIOKI, and must be purchased from a separate vendor.
 
 
Basic specifications (Accuracy guaranteed for 1 year)
No. of connectable units Maximum 8 units (total 120 channels), Bundle 8 Modules together to achieve a 120-channel System, Bundle 5 Systems together to enable a maximum of 600 channels of simultaneous recording
Measurement parameters
Model 8948
Voltage : ±150mV to ±100V, 1-5V f.s. 6 ranges, Max. resolution 5µV
Temperature (thermocouples) : -200°C to 2000°C (depend on the sensor), 3 range (K, E, J, T, N, W (Wre5-26), R, S, B), Max. resolution 0.01°C
Max. allowable input : DC 100V, Max. rated voltage between channels : 200 V DC, Max. rated voltage to earth : 600 V DC, AC
Measurement parameters
Model 8949
Voltage : ±150mV to ±60V, 1-5V f.s. 6 range, Max. resolution 5µV
Temperature (thermocouples) : -200°C to 2000°C (depend on the sensor), 3 range (K, E, J, T, N, W (Wre5-26), R, S, B), Max. resolution 0.01°C
Temperature (Resistance temperature sensor) : -200°C to 800°C, 3 range (Pt 100, JPt 100), Max. resolution 0.01°C
Humidity : 100% rh f.s., 5.0 to 95.0% rh (use with the 9701), resolution 0.1% rh
Max. allowable input : DC 60V, Max. rated voltage between channels : 120 V DC, Max. rated voltage to earth : 600 V DC, AC
Measurement parameters
Model 8996
Totalized pulses : 0 to 1000M pulse, 1 range (No-voltage 'a' contact, open collector or voltage input), Max. resolution 1 pulse
Rotation count : 0 to 5000/n (r/s) f.s. 1 range (No-voltage 'a' contact, open collector or voltage input), Resolution 1/n (r/s) Note: n = pulses per rotation (1 to 1,000)
Digital input : ON/OFF digital signal
Max. allowable input : DC 50V, Max. rated voltage between channels : 33V AC, 70V DC, Max. rated voltage to earth : 600 V DC, AC, (Upper limit voltage that does not cause damage when applied between CH-1 to CH-5 each channel and chassis, CH-6 to CH-10 each channel and chassis, CH-11 to CH-15 each channel and chassis, and between each UNITs), (common ground for CH-1 to CH-5, common ground for CH-6 to CH-10, common ground for CH-11 to CH-15)
Recording intervals 10ms to 1hr, 19 range (5s to 1hr when combined with humidity measurement), Dual sampling : Recording intervals can be specified for every input module (high-speed and low-speed)
Function Measurement data are saved to the CF Card in real time, Trigger function, Digital filter (Input unit), Alarm output (use with the ALARM UNIT 8997), Data acquisition is controlled by the PC data acquisition program, FTP server function, HTTP server function
Interface LAN : supports 100Base-TX, USB : Ver 2.0, mini-B receptacle, CF card slot
Power supply Using the AC ADAPTER 9418-15 /20 VA (when connected with 8 units), 12V Battery (voltage may range from -20% to +30%, Please contact HIOKI for connection cord).
Dimensions & Mass 67 mm (2.64 in) W × 133 mm (5.24 in) H × 125 mm (4.92 in) D, 600 g (21.2 oz) (main unit 8423 only)
Accessories Operating Manual ×1, Quick Start Manual ×1, AC ADAPTER 9418-15 ×1, USB cable ×1, Connection Plate ×1, CD-R (data collection software "LOGGER UTILITY") ×1, Connector cover ×1, Ferrite clamp ×1